Northlight Home Inspections
Inspected November 21, 2026
Definition of condition terms
Scope and limitations
This is a visual, non-invasive inspection of readily accessible systems and components, performed in general accordance with the Washington State Standards of Practice for home inspectors. It is not a building-code inspection, a warranty, a guarantee, an insurance policy, or a substitute for seller disclosure.
Concealed, unsafe, or inaccessible areas are outside the scope. The inspector is a generalist. Where further evaluation is recommended, the client should retain a licensed specialist at the client’s expense. This report is prepared solely for the named client. Liability is limited as stated in the signed pre-inspection agreement, typically to a refund of the fee paid.
Summary of flagged items
Informational comments stay in the body of the report. This summary lists conditions rated Marginal, Repair or Replace, Further Evaluation, or Safety Hazard. It is not a repair contract or a cost estimate.
Exterior receptacles were not GFCI protected and/or lacked weather-resistant covers. Have a qualified electrician install GFCI protection and in-use covers.
Smoke and/or carbon monoxide alarm coverage is incomplete relative to current Washington practice. Install or replace alarms as required before occupancy.
Vegetation is in contact with the siding. Trim plants back 6–12 inches from the building to reduce moisture retention and wood-destroying organism risk.
Gutters and downspouts contain debris and are not draining freely. Clean and flush the system, and confirm downspouts discharge away from the foundation.
Kick-out flashing is missing at roof-to-wall intersections. Have a qualified roofer install kick-out flashing to reduce moisture damage to siding.
GFCI protection is missing at the kitchen counter and garage receptacles sampled.
The crawlspace vapor barrier is incomplete or disturbed. Repair or replace the barrier so soil is fully covered and seams are overlapped.
Finish grading appears to slope toward the foundation in this area. Regrade to drain surface water away from the structure.
The HVAC filter is dirty or overdue for replacement. Replace the filter and establish a regular maintenance schedule.
Panel labeling is incomplete and a knockout is open. Further evaluation by a qualified electrician is recommended.
Evidence of rodent activity was observed (droppings and/or damaged insulation). Further evaluation and mitigation by a licensed pest control operator is recommended.
Repair request list (for agents)
Generated from flagged items so the buyer’s agent can start a request. It is not a demand, and it does not replace negotiation or specialist estimates.
- Have a qualified electrician install GFCI protection and in-use covers at exterior receptacles, and GFCI protection at kitchen and garage receptacles that lacked it.
- Install or replace smoke and carbon monoxide alarms to current Washington practice before occupancy.
- Trim vegetation 6–12 inches off the siding; clean gutters and extend downspouts; correct grading that slopes toward the foundation.
- Have a qualified roofer install kick-out flashing at roof-to-wall intersections.
- Repair or replace the crawlspace vapor barrier so soil is fully covered.
- Have a qualified electrician evaluate the service panel (open knockout, incomplete labeling).
- Have a licensed pest control operator evaluate and mitigate visible rodent activity.
Section notes (selected)
Roofing
Satisfactory Composition shingles appear consistent with mid-life wear. No active leaking was observed from the ground and at the eaves. Flashings at kick-out locations are a separate repair item above.
Plumbing
Satisfactory The 40-gallon electric water heater operated at the time of inspection. TPR piping is present and terminated adequately. Visible supply and drain lines showed no active leaking.
HVAC
The heating system responded to normal operating controls. The filter should be replaced as noted.
Structure, attic, and crawlspace
Visible foundation and framing were generally consistent with a house of this age. The attic was accessible. Crawlspace vapor barrier and pest evidence are called out in the summary.
Closing
Please read the entire report, not only this summary. If a recommendation calls for further evaluation, have that work performed by a qualified, licensed professional before the end of your contingency period. This sample uses fictional client and property information. A live report in the client portal reflects the signed agreement, payment status, and on-site findings for that work order.
© 2026 Northlight Home Inspections · Mockup sample · Not a real inspection of a real property.