Confidential inspection report

Northlight Home Inspections

Everett, Washington · (425) 555-0148
WA Home Inspector License #HI123456 (placeholder)
InterNACHI member · ASHI associate (placeholders) · E&O insured
WO-1048
Inspected November 21, 2026
Street view of 1842 Cedar Lane, a two-story home in Edmonds Cover photo · 1842 Cedar Lane, Edmonds, WA
Prepared for Priya & James Chen
Agent Erin Walsh, Windermere
Property 1842 Cedar Lane, Edmonds, WA 98020
County Snohomish
Year built / size 1988 · 2,180 sq ft · 4 bed / 2.5 bath
Inspector Matt Johnson
Service Buyer’s home inspection + Pest / WDO
Fee $620.00 (paid)
Satisfactory Marginal Repair or Replace Further Evaluation Safety Hazard

Definition of condition terms

Satisfactory. At the time of inspection the component is functional without observed signs of a substantial defect.
Marginal. The component is functioning but appears to be nearing the end of its useful life. Maintenance is recommended; replacement should be anticipated.
Repair or Replace. The component does not function as intended or presents a condition that should be corrected. Repair or replacement is recommended.
Further Evaluation. The component needs further technical or invasive evaluation by a qualified specialist to determine the nature of any defect, the corrective action, and any associated cost.
Safety Hazard. The condition may cause harm to people or property and should be addressed promptly by a qualified professional.

Scope and limitations

This is a visual, non-invasive inspection of readily accessible systems and components, performed in general accordance with the Washington State Standards of Practice for home inspectors. It is not a building-code inspection, a warranty, a guarantee, an insurance policy, or a substitute for seller disclosure.

Concealed, unsafe, or inaccessible areas are outside the scope. The inspector is a generalist. Where further evaluation is recommended, the client should retain a licensed specialist at the client’s expense. This report is prepared solely for the named client. Liability is limited as stated in the signed pre-inspection agreement, typically to a refund of the fee paid.

Summary of flagged items

Informational comments stay in the body of the report. This summary lists conditions rated Marginal, Repair or Replace, Further Evaluation, or Safety Hazard. It is not a repair contract or a cost estimate.

Exterior receptacles and lightingSafety Hazard

Exterior receptacles were not GFCI protected and/or lacked weather-resistant covers. Have a qualified electrician install GFCI protection and in-use covers.

Exterior wall and porch area where receptacles were sampledRear porch · timestamped in the liability vault
Smoke and carbon monoxide alarmsSafety Hazard

Smoke and/or carbon monoxide alarm coverage is incomplete relative to current Washington practice. Install or replace alarms as required before occupancy.

Vegetation and site conditionsRepair or Replace

Vegetation is in contact with the siding. Trim plants back 6–12 inches from the building to reduce moisture retention and wood-destroying organism risk.

Shrubs growing against home sidingEast elevation · vegetation at siding
Gutters and downspoutsRepair or Replace

Gutters and downspouts contain debris and are not draining freely. Clean and flush the system, and confirm downspouts discharge away from the foundation.

Flashings, valleys, and kick-outsRepair or Replace

Kick-out flashing is missing at roof-to-wall intersections. Have a qualified roofer install kick-out flashing to reduce moisture damage to siding.

Roof-to-wall intersectionRoof-to-wall intersection · missing kick-out flashing
GFCI / AFCI protectionRepair or Replace

GFCI protection is missing at the kitchen counter and garage receptacles sampled.

Vapor barrierRepair or Replace

The crawlspace vapor barrier is incomplete or disturbed. Repair or replace the barrier so soil is fully covered and seams are overlapped.

Below-floor framing area typical of a crawlspace accessCrawlspace · incomplete vapor barrier
Grading and surface drainageMarginal

Finish grading appears to slope toward the foundation in this area. Regrade to drain surface water away from the structure.

Filter and accessMarginal

The HVAC filter is dirty or overdue for replacement. Replace the filter and establish a regular maintenance schedule.

Service panel and labelingFurther Evaluation

Panel labeling is incomplete and a knockout is open. Further evaluation by a qualified electrician is recommended.

Rodent or other pest activity (visible)Further Evaluation

Evidence of rodent activity was observed (droppings and/or damaged insulation). Further evaluation and mitigation by a licensed pest control operator is recommended.

Repair request list (for agents)

Generated from flagged items so the buyer’s agent can start a request. It is not a demand, and it does not replace negotiation or specialist estimates.

  1. Have a qualified electrician install GFCI protection and in-use covers at exterior receptacles, and GFCI protection at kitchen and garage receptacles that lacked it.
  2. Install or replace smoke and carbon monoxide alarms to current Washington practice before occupancy.
  3. Trim vegetation 6–12 inches off the siding; clean gutters and extend downspouts; correct grading that slopes toward the foundation.
  4. Have a qualified roofer install kick-out flashing at roof-to-wall intersections.
  5. Repair or replace the crawlspace vapor barrier so soil is fully covered.
  6. Have a qualified electrician evaluate the service panel (open knockout, incomplete labeling).
  7. Have a licensed pest control operator evaluate and mitigate visible rodent activity.

Section notes (selected)

Roofing

Satisfactory Composition shingles appear consistent with mid-life wear. No active leaking was observed from the ground and at the eaves. Flashings at kick-out locations are a separate repair item above.

Plumbing

Satisfactory The 40-gallon electric water heater operated at the time of inspection. TPR piping is present and terminated adequately. Visible supply and drain lines showed no active leaking.

HVAC

The heating system responded to normal operating controls. The filter should be replaced as noted.

Structure, attic, and crawlspace

Visible foundation and framing were generally consistent with a house of this age. The attic was accessible. Crawlspace vapor barrier and pest evidence are called out in the summary.

Closing

Please read the entire report, not only this summary. If a recommendation calls for further evaluation, have that work performed by a qualified, licensed professional before the end of your contingency period. This sample uses fictional client and property information. A live report in the client portal reflects the signed agreement, payment status, and on-site findings for that work order.

© 2026 Northlight Home Inspections · Mockup sample · Not a real inspection of a real property.